Yealink: Wxx Factory Resetting The DECT Base

Yealink: Wxx Factory Resetting The DECT Base

Empire Telecom · Yealink

Open a ticket →Where: Want us to do it for you? Customer portal > New ticket (top bar).
Direct link: https://empiretelecom.io/portal/#/tickets/new

In the following guide, we will walk you through the process of resetting the Yealink W60, W70, and W76 cordless base stations to their default settings

Screenshot
IMPORTANT
These instructions will reset the DECT Base to factory default.
Factory resetting the DECT Base 

To factory reset the base:

a) From the handset menu:

1Press the OK button.
2Select Settings.
3Select System Settings.
4Select Base Reset.
5Enter the PIN (default: 0000), and press the Done soft key
6Press OK to confirm.

b) From the DECT base unit:

1Power off the unit by unplugging the power source.
2Wait for 15 seconds, then press and hold the connect button on the base station.
3While still holding the connect button, reconnect the power source.
4Wait until all three lights on the unit are showing as solid green, then release the connect button.
5Wait approximately 5 minutes.
6Reboot the unit by unplugging the power source for 15 seconds, then reconnect.
Screenshot
NOTE
After the base is factory reset, you may need to re-register the handset(s) to the base.
1Approach the DECT base with the handset.
2Long press the Wireless button on the base until the registration LED flashes.
3Press the OK soft key on the handset.
4Select Settings.
5Select System Settings.
6Select Register Handset.
7Select the desired base and then press the OK soft key to search.
8Press the OK soft key after searching a base successfully.
9Enter the base PIN (default: 0000), and then press the Done soft key.

Image

Need a hand? Call Empire Telecom support at (732) 363-9898, email support@empiretelecomnj.com, or open a ticket in the customer portal.